24-pair thermowire
Length 50 m
Technical data:
- Thermocouple combination: NiCr-Ni Type “K” / 24-pair
- Limiting deviation: Class 1, DIN IEC 584 Part 2, +/- 1.5 °C or 0.004 x | t |
- Stranded conductor: stranded, AWG 24F, 24 x 2 x 0.22 mm² (7 x 0.2 mm)
- Conductor insulation: FEP Teflon
- Conductor guide: stranded
- Braiding: Cu tin-plated
- Outer sheathing: FEP Teflon
- Operating temperature: -100 °C to +200 °C
- Outer dimension: approx. 10 mm round
- Sheathing colour: green
- Core colour: + = green, – = white