Type “L”
Fibreglass
- G/G-24-L-DIN
- G/GSTW-24F-2 x L-DIN
- G/GSTW-24F-L-DIN
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Wire, 2 x 0.5 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.1 x 1.5 mm.
Sheath colour: white with blue stripe.
Colour code for conductors according IEC 584: + = red, - = blue.
Technical data:
Thermo wires: 2 x Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Strand, 2 x 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Shielding: Fibreglass.
Outer sheath: armoured VA braid.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 4.0 mm round.
Sheath colour: silver with blue stripe.
Colour code for conductors according IEC 584: 2 x + = red, 2 x - = blue.
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0,2 mm).
Conductor insulation: Fibreglass.
Conductor routing: twisted with fibreglass filler and other jacket.
Outer sheath: armoured VA braid.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.5 mm round.
Sheath colour: silver with blue stripe.
Colour code for conductors according IEC 584: + = red, - = blue.