Type “L”

Teflon

  • TEX/SiTW-24F-L-DIN
  • Technical data:

    Thermo wires: Fe-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3.0 °C.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: PTFE-Teflon.
    Conductor routing: twisted.
    Outer sheath: Silicon.
    Operating temperature: -80 °C to +180 °C.
    Outer dimensions: approx. 3.5 mm round.
    Sheath colour: blue.
    Colour code for conductors according IEC 584: + = red, - = blue.

  • TEXTW-24F-L-DIN
  • Technical data:

    Thermo wires: Fe-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3.0 °C.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: open twisted.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.3 mm round.
    Colour code for conductors according IEC 584: + = red, - = blue.

  • TF/TF-24F-L-DIN
  • Technical data:

    Thermo wires: Fe-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3.0 °C.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: PTFE-Teflon.
    Conductor routing: parallel.
    Outer sheath: PTFE-Teflon.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 3.0 mm x 1.8 mm.
    Sheath colour: blue.
    Colour code for conductors according IEC 584: + = red, - = blue.

  • TEX/CUTEXTW-24F-L-DIN
  • Technical data:

    Thermo wires: Fer-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3,0 °C.
    Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: twisted.
    Shielding: Tinned copper, 85 % over braided.
    Outer sheath: FEP-Teflon.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 3.0 mm round.
    Sheath colour: blue.
    Colour code for conductors according IEC 584: + = red, - = blue.

Fibreglass

  • G/G-24-L-DIN
  • Technical data:

    Thermo wires: Fe-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3.0 °C.
    Solid conductor: Wire, 2 x 0.5 mm.
    Conductor insulation: Fibreglass.
    Conductor routing: parallel.
    Outer sheath: Fibreglass.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 2.1 x 1.5 mm.
    Sheath colour: white with blue stripe.
    Colour code for conductors according IEC 584: + = red, - = blue.

  • G/GSTW-24F-2 x L-DIN
  • Technical data:

    Thermo wires: 2 x Fe-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3.0 °C.
    Solid conductor: Strand, 2 x 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: Fibreglass.
    Conductor routing: parallel.
    Shielding: Fibreglass.
    Outer sheath: armoured VA braid.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 4.0 mm round.
    Sheath colour: silver with blue stripe.
    Colour code for conductors according IEC 584: 2 x + = red, 2 x - = blue.

  • G/GSTW-24F-L-DIN
  • Technical data:

    Thermo wires: Fe-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3.0 °C.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0,2 mm).
    Conductor insulation: Fibreglass.
    Conductor routing: twisted with fibreglass filler and other jacket.
    Outer sheath: armoured VA braid.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 2.5 mm round.
    Sheath colour: silver with blue stripe.
    Colour code for conductors according IEC 584: + = red, - = blue.

Kapton

  • KFD-30-L-DIN
  • KFD-30-L-DIN

    Technical data:

    Thermo wires: Fe-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3.0 °C.
    Stranded conductor: Wire 2 x 0.2 mm.
    Conductor insulation: Kapton.
    Conductor routing: parallel.
    Outer sheath: Kapton.
    Operating temperature: -265 °C to +285 °C.
    Outer dimensions: approx. 0.8 x 0.7 mm.
    Sheath colour: brown.
    Colour code for conductors according IEC 584: + = brown (magnetic),
    - = brown.

Other

  • PVC – P/PTW-24F-L-DIN
  • Technical data:

    Thermo wires: Fe-CuNi type “L”.
    Limit deviation: DIN 43710, +/-3.0 °C.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: PVC.
    Conductor routing: twisted.
    Outer sheath: PVC.
    Operating temperature: -20 °C to +70 °C.
    Outer dimensions: approx. 3.5 mm round.
    Colour code for conductors according IEC 584: + = red, - = blue.