Type “L”
Teflon
- TEX/SiTW-24F-L-DIN
- TEXTW-24F-L-DIN
- TF/TF-24F-L-DIN
- TEX/CUTEXTW-24F-L-DIN
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: PTFE-Teflon.
Conductor routing: twisted.
Outer sheath: Silicon.
Operating temperature: -80 °C to +180 °C.
Outer dimensions: approx. 3.5 mm round.
Sheath colour: blue.
Colour code for conductors according IEC 584: + = red, - = blue.
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: open twisted.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.3 mm round.
Colour code for conductors according IEC 584: + = red, - = blue.
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: PTFE-Teflon.
Conductor routing: parallel.
Outer sheath: PTFE-Teflon.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 3.0 mm x 1.8 mm.
Sheath colour: blue.
Colour code for conductors according IEC 584: + = red, - = blue.
Technical data:
Thermo wires: Fer-CuNi type “L”.
Limit deviation: DIN 43710, +/-3,0 °C.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: twisted.
Shielding: Tinned copper, 85 % over braided.
Outer sheath: FEP-Teflon.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 3.0 mm round.
Sheath colour: blue.
Colour code for conductors according IEC 584: + = red, - = blue.
Fibreglass
- G/G-24-L-DIN
- G/GSTW-24F-2 x L-DIN
- G/GSTW-24F-L-DIN
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Wire, 2 x 0.5 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.1 x 1.5 mm.
Sheath colour: white with blue stripe.
Colour code for conductors according IEC 584: + = red, - = blue.
Technical data:
Thermo wires: 2 x Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Strand, 2 x 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Shielding: Fibreglass.
Outer sheath: armoured VA braid.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 4.0 mm round.
Sheath colour: silver with blue stripe.
Colour code for conductors according IEC 584: 2 x + = red, 2 x - = blue.
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0,2 mm).
Conductor insulation: Fibreglass.
Conductor routing: twisted with fibreglass filler and other jacket.
Outer sheath: armoured VA braid.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.5 mm round.
Sheath colour: silver with blue stripe.
Colour code for conductors according IEC 584: + = red, - = blue.
Kapton
- KFD-30-L-DIN
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Stranded conductor: Wire 2 x 0.2 mm.
Conductor insulation: Kapton.
Conductor routing: parallel.
Outer sheath: Kapton.
Operating temperature: -265 °C to +285 °C.
Outer dimensions: approx. 0.8 x 0.7 mm.
Sheath colour: brown.
Colour code for conductors according IEC 584: + = brown (magnetic),
- = brown.
Other
- PVC – P/PTW-24F-L-DIN
Technical data:
Thermo wires: Fe-CuNi type “L”.
Limit deviation: DIN 43710, +/-3.0 °C.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: PVC.
Conductor routing: twisted.
Outer sheath: PVC.
Operating temperature: -20 °C to +70 °C.
Outer dimensions: approx. 3.5 mm round.
Colour code for conductors according IEC 584: + = red, - = blue.