Type “K”
Other:
- PVC – P/CUPTW-24F-KX-IEC
- Silicon – Si/SiTW-24F-KK-IEC
Technical data:
Thermo wires: NiCr-Ni type “K”, compensating cables.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: PVC.
Conductor routing: twisted.
Shielding: Tinned copper, 85 % over braided.
Outer sheath: PVC.
Operating temperature: -20 °C to +70 °C.
Outer dimensions: approx. 4.5 mm round.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: Silicon.
Conductor routing: twisted.
Outer sheath: Silicon.
Operating temperature: -50 °C to +180 °C.
Outer dimensions: approx. 3.5 mm round.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.