Type “K”

Kapton

  • KFD-24-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0,004 x | t |.
    Solid conductor: Wire, 2 x 0.5 mm.
    Conductor insulation: Kapton.
    Conductor routing: parallel.
    Outer sheath: Kapton.
    Operating temperature: -265 °C to +285 °C.
    Outer dimensions: approx. 1.8 x 1.2 mm.
    Sheath colour: brown.
    Colour code for conductors according IEC 584: + = brown, - = brown (magnetic).

  • KFD-30-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Solid conductor: Wire, 2 x 0.2 mm.
    Conductor insulation: Kapton.
    Conductor routing: parallel.
    Outer sheath: Kapton.
    Operating temperature: -265 °C to +285 °C.
    Outer dimensions: approx. 0.8 x 0.7 mm.
    Sheath colour: brown.
    Colour code for conductors according IEC 584: + = brown, - = brown (magnetic).

  • KFD-TW-18F-KK-ASA
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Solid conductor: Strand, 2 x 0.89 mm² (7 x 0.4 mm).
    Conductor insulation: Kapton.
    Conductor routing: open twisted.
    Operating temperature: -265 °C to +285 °C.
    Colour code for conductors according IEC 584: + = yellow, - = red.