Type “K”
Kapton
- KFD-24-KK-IEC
- KFD-30-KK-IEC
- KFD-TW-18F-KK-ASA
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0,004 x | t |.
Solid conductor: Wire, 2 x 0.5 mm.
Conductor insulation: Kapton.
Conductor routing: parallel.
Outer sheath: Kapton.
Operating temperature: -265 °C to +285 °C.
Outer dimensions: approx. 1.8 x 1.2 mm.
Sheath colour: brown.
Colour code for conductors according IEC 584: + = brown, - = brown (magnetic).
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Wire, 2 x 0.2 mm.
Conductor insulation: Kapton.
Conductor routing: parallel.
Outer sheath: Kapton.
Operating temperature: -265 °C to +285 °C.
Outer dimensions: approx. 0.8 x 0.7 mm.
Sheath colour: brown.
Colour code for conductors according IEC 584: + = brown, - = brown (magnetic).
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Strand, 2 x 0.89 mm² (7 x 0.4 mm).
Conductor insulation: Kapton.
Conductor routing: open twisted.
Operating temperature: -265 °C to +285 °C.
Colour code for conductors according IEC 584: + = yellow, - = red.