Type “K”
Fibreglass
- G/G-20-KK-ANSI
- G/G-24-KK-IEC
- G/G-30-KK-IEC
- G/GSTW-24F-KK-IEC
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Wire, 2 x 0.8 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.4 x 1.4 mm.
Sheath colour: white with yellow stripe.
Colour code for conductors according IEC 584: + = yellow, - = red.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0,004 x | t |.
Solid conductor: Wire, 2 x 0.5 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.1 x 1.5 mm.
Sheath colour: white with green stripe.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0,004 x | t |.
Solid conductor: Wire, 2 x 0.2 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 1.4 x 1.0 mm.
Sheath colour: white with green stripe.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: Fibreglass.
Conductor routing: twisted with fibreglass filler and other jacket.
Outer sheath: armoured VA shielding.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 3.2 mm round.
Sheath colour: silver with green stripe.