Type “K”

Teflon

  • TEX/CUTEXTW-12 x 24F-KK-IEC (also available ex-stock in 4-, 6-, 10-, 12-, 20- or 24-pair)
  • Technical data:

    Thermo wires: 24 x NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Stranded conductor: Strand, 12 x 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: twisted.
    Shielding: Tinned copper, 85 % over braided.
    Outer sheath: FEP-Teflon.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 10 mm round.
    Sheath colour: green.
    Colour code for conductors according IEC 584: + = green, - = white.

  • TEX/CUTEXTW-24F-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: twisted.
    Shielding: Tinned copper, 85 % over braided.
    Outer sheath: FEP-Teflon.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 3.0 mm round.
    Sheath colour: green.
    Colour code for conductors according IEC 584: + = green, - = white.

  • TEX/TEXTW-24F-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: twisted.
    Outer sheath: FEP-Teflon.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.0 mm round.
    Sheath colour: green.
    Colour code for conductors according IEC 584: + = green, - = white.

  • TEX/TEXTW-30-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Solid conductor: Wire, 2 x 0.2 mm.
    Conductor insulation: FEP-Teflon.
    Conductor routing: twisted.
    Outer sheath: FEP-Teflon.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.0 mm round.
    Sheath colour: green.
    Colour code for conductors according IEC 584: + = green, - = white.

  • TEXTW-24F-KK-ANSI
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: open twisted.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.3 mm round.
    Colour code for conductors according IEC 584: + = yellow, - = red.

  • TEXTW-24F-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: open twisted.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.3 mm round.
    Colour code for conductors according IEC 584: + = green, - = white.

  • TF/TF-24F-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: parallel.
    Outer sheath: FEP-Teflon.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.2 x 1.3 mm.
    Sheath colour: green.
    Colour code for conductors according IEC 584: + = green, - = white.

Fibreglass

  • G/G-20-KK-ANSI
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Solid conductor: Wire, 2 x 0.8 mm.
    Conductor insulation: Fibreglass.
    Conductor routing: parallel.
    Outer sheath: Fibreglass.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 2.4 x 1.4 mm.
    Sheath colour: white with yellow stripe.
    Colour code for conductors according IEC 584: + = yellow, - = red.

  • G/G-24-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0,004 x | t |.
    Solid conductor: Wire, 2 x 0.5 mm.
    Conductor insulation: Fibreglass.
    Conductor routing: parallel.
    Outer sheath: Fibreglass.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 2.1 x 1.5 mm.
    Sheath colour: white with green stripe.
    Colour code for conductors according IEC 584: + = green, - = white.

  • G/G-30-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0,004 x | t |.
    Solid conductor: Wire, 2 x 0.2 mm.
    Conductor insulation: Fibreglass.
    Conductor routing: parallel.
    Outer sheath: Fibreglass.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 1.4 x 1.0 mm.
    Sheath colour: white with green stripe.
    Colour code for conductors according IEC 584: + = green, - = white.

  • G/GSTW-24F-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: Fibreglass.
    Conductor routing: twisted with fibreglass filler and other jacket.
    Outer sheath: armoured VA shielding.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 3.2 mm round.
    Sheath colour: silver with green stripe.
    Colour code for conductors according IEC 584: + = green, - = white.

Kapton

  • KFD-24-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0,004 x | t |.
    Solid conductor: Wire, 2 x 0.5 mm.
    Conductor insulation: Kapton.
    Conductor routing: parallel.
    Outer sheath: Kapton.
    Operating temperature: -265 °C to +285 °C.
    Outer dimensions: approx. 1.8 x 1.2 mm.
    Sheath colour: brown.
    Colour code for conductors according IEC 584: + = brown, - = brown (magnetic).

  • KFD-30-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Solid conductor: Wire, 2 x 0.2 mm.
    Conductor insulation: Kapton.
    Conductor routing: parallel.
    Outer sheath: Kapton.
    Operating temperature: -265 °C to +285 °C.
    Outer dimensions: approx. 0.8 x 0.7 mm.
    Sheath colour: brown.
    Colour code for conductors according IEC 584: + = brown, - = brown (magnetic).

  • KFD-TW-18F-KK-ASA
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Solid conductor: Strand, 2 x 0.89 mm² (7 x 0.4 mm).
    Conductor insulation: Kapton.
    Conductor routing: open twisted.
    Operating temperature: -265 °C to +285 °C.
    Colour code for conductors according IEC 584: + = yellow, - = red.

Other:

  • PVC – P/CUPTW-24F-KX-IEC
  • PVC – P/CUPTW-24F-KX-IEC

    Technical data:

    Thermo wires: NiCr-Ni type “K”, compensating cables.
    Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: PVC.
    Conductor routing: twisted.
    Shielding: Tinned copper, 85 % over braided.
    Outer sheath: PVC.
    Operating temperature: -20 °C to +70 °C.
    Outer dimensions: approx. 4.5 mm round.
    Sheath colour: green.
    Colour code for conductors according IEC 584: + = green, - = white.

  • Silicon – Si/SiTW-24F-KK-IEC
  • Technical data:

    Thermo wires: NiCr-Ni type “K”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0.004 x | t |.
    Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: Silicon.
    Conductor routing: twisted.
    Outer sheath: Silicon.
    Operating temperature: -50 °C to +180 °C.
    Outer dimensions: approx. 3.5 mm round.
    Sheath colour: green.