Technical data:
Thermo wires: 24 x NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Stranded conductor: Strand, 12 x 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: twisted.
Shielding: Tinned copper, 85 % over braided.
Outer sheath: FEP-Teflon.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 10 mm round.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: twisted.
Shielding: Tinned copper, 85 % over braided.
Outer sheath: FEP-Teflon.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 3.0 mm round.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: twisted.
Outer sheath: FEP-Teflon.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.0 mm round.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Wire, 2 x 0.2 mm.
Conductor insulation: FEP-Teflon.
Conductor routing: twisted.
Outer sheath: FEP-Teflon.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.0 mm round.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: open twisted.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.3 mm round.
Colour code for conductors according IEC 584: + = yellow, - = red.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: open twisted.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.3 mm round.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: parallel.
Outer sheath: FEP-Teflon.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.2 x 1.3 mm.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.
Fibreglass
- G/G-20-KK-ANSI
- G/G-24-KK-IEC
- G/G-30-KK-IEC
- G/GSTW-24F-KK-IEC
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Wire, 2 x 0.8 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.4 x 1.4 mm.
Sheath colour: white with yellow stripe.
Colour code for conductors according IEC 584: + = yellow, - = red.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0,004 x | t |.
Solid conductor: Wire, 2 x 0.5 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.1 x 1.5 mm.
Sheath colour: white with green stripe.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0,004 x | t |.
Solid conductor: Wire, 2 x 0.2 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 1.4 x 1.0 mm.
Sheath colour: white with green stripe.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: Fibreglass.
Conductor routing: twisted with fibreglass filler and other jacket.
Outer sheath: armoured VA shielding.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 3.2 mm round.
Sheath colour: silver with green stripe.
Colour code for conductors according IEC 584: + = green, - = white.
Kapton
- KFD-24-KK-IEC
- KFD-30-KK-IEC
- KFD-TW-18F-KK-ASA
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0,004 x | t |.
Solid conductor: Wire, 2 x 0.5 mm.
Conductor insulation: Kapton.
Conductor routing: parallel.
Outer sheath: Kapton.
Operating temperature: -265 °C to +285 °C.
Outer dimensions: approx. 1.8 x 1.2 mm.
Sheath colour: brown.
Colour code for conductors according IEC 584: + = brown, - = brown (magnetic).
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Wire, 2 x 0.2 mm.
Conductor insulation: Kapton.
Conductor routing: parallel.
Outer sheath: Kapton.
Operating temperature: -265 °C to +285 °C.
Outer dimensions: approx. 0.8 x 0.7 mm.
Sheath colour: brown.
Colour code for conductors according IEC 584: + = brown, - = brown (magnetic).
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Solid conductor: Strand, 2 x 0.89 mm² (7 x 0.4 mm).
Conductor insulation: Kapton.
Conductor routing: open twisted.
Operating temperature: -265 °C to +285 °C.
Colour code for conductors according IEC 584: + = yellow, - = red.
Other:
- PVC – P/CUPTW-24F-KX-IEC
- Silicon – Si/SiTW-24F-KK-IEC
Technical data:
Thermo wires: NiCr-Ni type “K”, compensating cables.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: PVC.
Conductor routing: twisted.
Shielding: Tinned copper, 85 % over braided.
Outer sheath: PVC.
Operating temperature: -20 °C to +70 °C.
Outer dimensions: approx. 4.5 mm round.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.
Technical data:
Thermo wires: NiCr-Ni type “K”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0.004 x | t |.
Stranded conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: Silicon.
Conductor routing: twisted.
Outer sheath: Silicon.
Operating temperature: -50 °C to +180 °C.
Outer dimensions: approx. 3.5 mm round.
Sheath colour: green.
Colour code for conductors according IEC 584: + = green, - = white.