Type “J”

Teflon

  • TEX/SiTW-24F-J-IEC
  • Technical data:

    Thermo wires: Fe-CuNi type “J”.
    Limit deviation: Class 2, DIN IEC 584 part 2,
    +/- 2.5 °C or 0.0075 x | t |.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: PTFE-Teflon.
    Conductor routing: twisted.
    Outer sheath: Silicon.
    Operating temperature: -80 °C to +180 °C.
    Outer dimensions: approx. 3.5 mm round.
    Sheath colour: black.
    Colour code for conductors according IEC 584: + = black, - = white.

  • TEXTW-24F-J-ANSI
  • Technical data:

    Thermo wires: Fe-CuNi type “J”.
    Limit deviation: Class 2, DIN IEC 584 part 2,
    +/- 2.5 °C or 0.0075 x | t |.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: open twisted.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.3 mm round.
    Colour code for conductors according IEC 584: + = white, - = red.

  • TEXTW-24F-J-IEC
  • Technical data:

    Thermo wires: Fe-CuNi type “J”.
    Limit deviation: Class 2, DIN IEC 584 part 2,
    +/- 2.5 °C or 0.0075 x | t |.
    Solid conductor: Strand, 2 x 0,22 mm² (7 x 0.2 mm).
    Conductor insulation: FEP-Teflon.
    Conductor routing: open twisted.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.3 mm round.
    Colour code for conductors according IEC 584: + = black, - = white.

  • TF/TF-24-J-IEC
  • Technical data:

    Thermo wires: Fe-CuNi type “J”.
    Limit deviation: Class 2, DIN IEC 584 part 2,
    +/- 2.5 °C or 0.0075 x | t |.
    Solid conductor: Wire, 2 x 0.5 mm.
    Conductor insulation: PTFE-Teflon.
    Conductor routing: parallel.
    Outer sheath: PTFE-Teflon.
    Operating temperature: -190 °C to +260 °C.
    Outer dimensions: approx. 2.7 mm x 1.6 mm.
    Sheath colour: black.
    Colour code for conductors according IEC 584: + = black, - = white.

Fibreglass

  • G/G-20-J-ANSI
  • Technical data:

    Thermo wires: Fe-CuNi type "J".
    Limit deviation: Class 2, DIN IEC 584 part 2,
    +/- 2.5 °C or 0,0075 x | t |.
    Solid conductor: Wire, 2 x 0.8 mm.
    Conductor insulation: Fibreglass.
    Conductor routing: parallel.
    Outer sheath: Fibreglass.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 2.8 x 1.9 mm.
    Sheath colour: white with black stripe.
    Colour code for conductors according IEC 584: + = white, - = red.

  • G/GSTW-24F-J-IEC
  • Technical data:

    Thermo wires: Fe-CuNi type "J".
    Limit deviation: Class 2, DIN IEC 584 part 2,
    +/- 2.5 °C or 0.0075 x | t |.
    Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
    Conductor insulation: Fibreglass.
    Conductor routing: twisted.
    Shielding: Fibreglass.
    Outer sheath: armoured VA braid.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 3.2 mm round.
    Sheath colour: silver with black stripe.
    Colour code for conductors according IEC 584: + = black, - = white.

  • G/G-30-JJ-IEC
  • Technical data:

    Thermo wires: Fe-CuNi type “J”.
    Limit deviation: Class 1, DIN IEC 584 part 2,
    +/- 1.5 °C or 0,004 x | t |.
    Solid conductor: Wire, 2 x 0.2 mm.
    Conductor insulation: Fibreglass.
    Conductor routing: parallel.
    Outer sheath: Fibreglass.
    Operating temperature: up to +450 °C.
    Outer dimensions: approx. 1.4 x 1.0 mm.
    Sheath colour: white with black stripe.
    Colour code for conductors according IEC 584: + = black, - = white.

Kapton

  • KFD-30-J-IEC
  • KFD-30-J-IEC

    Technical data:

    Thermo wires: Fe-CuNi type “J”.
    Limit deviation: Class 2, DIN IEC 584 part 2,
    +/- 2.5 °C or 0.0075 x | t |.
    Stranded conductor: Wire, 2 x 0.2 mm.
    Conductor insulation: Kapton.
    Conductor routing: parallel.
    Outer sheath: Kapton.
    Operating temperature: -265 °C to +285 °C.
    Outer dimensions: approx. 0.8 x 0.7 mm.
    Sheath colour: brown.
    Colour code for conductors according IEC 584: + = brown (magnetic), - = brown.

Other

  • Silicon – Si/SiTW-24-JX-IEC
  • Technical data:

    Thermo wires: Fe-CuNi type “J”, compensating cable.
    Solid conductor: Wire, 2 x 0.5 mm.
    Conductorisolation: Silicon.
    Conductor routing: twisted.
    Outer sheath: Silicon.
    Operating temperature: -50 °C to +180 °C.
    Outer dimensions: approx. 4.0 mm round.
    Sheath colour: black.