Type “J”
Teflon
- TEX/SiTW-24F-J-IEC
- TEXTW-24F-J-ANSI
- TEXTW-24F-J-IEC
- TF/TF-24-J-IEC
Technical data:
Thermo wires: Fe-CuNi type “J”.
Limit deviation: Class 2, DIN IEC 584 part 2,
+/- 2.5 °C or 0.0075 x | t |.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: PTFE-Teflon.
Conductor routing: twisted.
Outer sheath: Silicon.
Operating temperature: -80 °C to +180 °C.
Outer dimensions: approx. 3.5 mm round.
Sheath colour: black.
Colour code for conductors according IEC 584: + = black, - = white.
Technical data:
Thermo wires: Fe-CuNi type “J”.
Limit deviation: Class 2, DIN IEC 584 part 2,
+/- 2.5 °C or 0.0075 x | t |.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: open twisted.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.3 mm round.
Colour code for conductors according IEC 584: + = white, - = red.
Technical data:
Thermo wires: Fe-CuNi type “J”.
Limit deviation: Class 2, DIN IEC 584 part 2,
+/- 2.5 °C or 0.0075 x | t |.
Solid conductor: Strand, 2 x 0,22 mm² (7 x 0.2 mm).
Conductor insulation: FEP-Teflon.
Conductor routing: open twisted.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.3 mm round.
Colour code for conductors according IEC 584: + = black, - = white.
Technical data:
Thermo wires: Fe-CuNi type “J”.
Limit deviation: Class 2, DIN IEC 584 part 2,
+/- 2.5 °C or 0.0075 x | t |.
Solid conductor: Wire, 2 x 0.5 mm.
Conductor insulation: PTFE-Teflon.
Conductor routing: parallel.
Outer sheath: PTFE-Teflon.
Operating temperature: -190 °C to +260 °C.
Outer dimensions: approx. 2.7 mm x 1.6 mm.
Sheath colour: black.
Colour code for conductors according IEC 584: + = black, - = white.
Fibreglass
- G/G-20-J-ANSI
- G/GSTW-24F-J-IEC
- G/G-30-JJ-IEC
Technical data:
Thermo wires: Fe-CuNi type "J".
Limit deviation: Class 2, DIN IEC 584 part 2,
+/- 2.5 °C or 0,0075 x | t |.
Solid conductor: Wire, 2 x 0.8 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 2.8 x 1.9 mm.
Sheath colour: white with black stripe.
Colour code for conductors according IEC 584: + = white, - = red.
Technical data:
Thermo wires: Fe-CuNi type "J".
Limit deviation: Class 2, DIN IEC 584 part 2,
+/- 2.5 °C or 0.0075 x | t |.
Solid conductor: Strand, 2 x 0.22 mm² (7 x 0.2 mm).
Conductor insulation: Fibreglass.
Conductor routing: twisted.
Shielding: Fibreglass.
Outer sheath: armoured VA braid.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 3.2 mm round.
Sheath colour: silver with black stripe.
Colour code for conductors according IEC 584: + = black, - = white.
Technical data:
Thermo wires: Fe-CuNi type “J”.
Limit deviation: Class 1, DIN IEC 584 part 2,
+/- 1.5 °C or 0,004 x | t |.
Solid conductor: Wire, 2 x 0.2 mm.
Conductor insulation: Fibreglass.
Conductor routing: parallel.
Outer sheath: Fibreglass.
Operating temperature: up to +450 °C.
Outer dimensions: approx. 1.4 x 1.0 mm.
Sheath colour: white with black stripe.
Colour code for conductors according IEC 584: + = black, - = white.
Kapton
- KFD-30-J-IEC
Technical data:
Thermo wires: Fe-CuNi type “J”.
Limit deviation: Class 2, DIN IEC 584 part 2,
+/- 2.5 °C or 0.0075 x | t |.
Stranded conductor: Wire, 2 x 0.2 mm.
Conductor insulation: Kapton.
Conductor routing: parallel.
Outer sheath: Kapton.
Operating temperature: -265 °C to +285 °C.
Outer dimensions: approx. 0.8 x 0.7 mm.
Sheath colour: brown.
Colour code for conductors according IEC 584: + = brown (magnetic), - = brown.
Other
- Silicon – Si/SiTW-24-JX-IEC
Technical data:
Thermo wires: Fe-CuNi type “J”, compensating cable.
Solid conductor: Wire, 2 x 0.5 mm.
Conductorisolation: Silicon.
Conductor routing: twisted.
Outer sheath: Silicon.
Operating temperature: -50 °C to +180 °C.
Outer dimensions: approx. 4.0 mm round.
Sheath colour: black.
Colour code for conductors according IEC 584: + = black, - = white.